Home/Products
  •  
    uFlamer® is a global pioneer of vertical fluid driven flamer, with flame height up to 8-10m. Equipped with built-in fuel tank and pumping system makes it super easy to setup and operate. The fuel for uFlamer is ISOPAR, which is much safer as well as less restrictions comparing with existing gas flamers on the market.IPX3 rated design and indoor nozzle optional ensure flexible usage of uFlamer®.
     

    Specifications:

    Model: uFlamer
    Dimension: 330 x 260 x 320 mm
    Weight: 14kg
    VOLTAGE: 100-240V, 50/60Hz
    POWER: 300W
    CONTROL: DMX
    INTERFACE: 3-pin&5-pin DMX IN/OUT
    FLAME HEIGHT: 8-10m (no wind)
    FUEL: ISOPROPANOL, ISOPAR-G,H,L,M
    FUEL TANK CAPACITY: 5L
    FUEL CONSUMPTION RATE: 60ml/s
    FUEL LEVEL SENSOR: YES
    EFFECT DIRECTION: Vertical
    LGNITION: High voltage electron ignition
    IGNITOR: Dual
    BUILT-IN BATTERY: OPTIONAL
    USAGE IN RAIN: YES
    Category: CIRCLE FLAMER
  • SHOWVEN FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners.
     

    Specifications:

    Dimension:250 x 200 x 410 mm
    Net Weight:15 kg
    Housing material:Aluminum
    Input:220V, 110V, 24V customizable
    Work power:120W
    Flame height:Up to 10m
    Fuel: ISOPAR
    Fuel consumption: 60ml/s (Nozzle M), 30ml/s (Nozzle L)
    Ignition: Dual, high voltage electron ignition
    Control: DMX, Direct ON-OFF customizable
    Quick Couplers: ISO7241B G1/4 male
    Work pressure range: 8-12bar
    Installation angles: Any direction even upside down
    Category: FLAMER
  • SHOWVEN 18m FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head X20, pump station P20H, accumulator model and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed.
     

    Specifications:

    Dimension:330 x 330 x 320 mm
    Weight:18 kg
    Housing material:304 stainless steel
    Input:AC100-240V, 50/60Hz
    Work power:100W
    Flame height:16-18m(no wind)
    Usage in Rain: Yes
    Fuel consumption:1000ml/s
    Ignition: Triple, high voltage electron ignition
    Control: DMX, 9-60V pyro signal
    Quick Couplers: ISO7241B G1/4 male
    Work pressure range: 40-60Bar
    Firing Angle: Vertical Up
    Installation Direction: Vertical Up
    Fuel: ISOPAR L (if use with uPumper P20H)
    Pressure Gauge: Yes, mechanical
    Min.Firing Duration: 0.2s
    Max.Firing Duration: 1s
     
    Category: FLAMER
  • SHOWVEN® FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. uFlamer X5 is a flame head with 5 output,each nozzle can be controlled independently.
     

    Specifications:

    Dimension:435×380×405 mm
    Weight:40 kg
    Housing material:304 stainless steel
    Input:AC100-240V, 50/60Hz
    Work power:400W
    Flame height:3-10m(no wind)
    Usage in Rain: Yes
    Ignition: Triple, high voltage electron ignition
    Control: DMX, 9-60V pyro signal
    Quick Couplers: ISO7241B G1/4 male
    Work pressure range: 8-12Bar
    Firing Angle: 5
    Installation Direction: Any direction
    Fuel: ISOPAR L
    Pressure Gauge: Yes, mechanical
     
    Category: FLAMER
  • SHOWVEN® KABUKI DROP is a compact and exquisite designed reliable device for drops of curtains, open up balloons, unroll of banners or any other objects on stages. It is a direct on-off system with 20kg loading capacity.
     

    Specifications:

    Dimension:76.5×82.5×230mm (clamps included)
    Weight:1 kg
    Input:110-120V / 220-240V,50/60Hz
    Work power:30W
    Load Capacity:20kg
    Control:Direct on-off voltage control
     
    Category: DROP
  • SHOWVEN® FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners.
     

    Specifications:

    Dimension:370 x 380 x 380 mm
    Net Weight:19 kg
    Housing material:304 Stainless steel
    Input:220V, 110V
    Work power:260W
    Flame height:Up to 10m
    USAGE IN RAIN: yes
    Quick Couplers: ISO7241B G1/4 male
    Min. firing duration: 0.1s
    Firing Angle: 210° (±105°)
    Fuel: ISOPAR
    Fuel consumption: 60ml/s (Nozzle M), 30ml/s (Nozzle L)
    Ignition: Dual, high voltage electron ignition
    Control: DMX, 9-60V Pyro signal
    USAGE IN RAIN: yes
    WORK PRESSURE RANGE: 8-12bar
    INSTALLATION ANGLES: Any direction,
    bottom plate need protective cover (optional) to achieve waterproof function
    Category: FLAMER
  • SHOWVEN FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. In order to meet the requirements of different application scenarios we designed two pump station (uPumper® P20 and uPumper® P4) and two flame heads (uFlamer® PF10 and uFlamer® X1800).

    Hose:

    High pressure steel wire braided rubber hose. Main hose is used to connect between uPumper® P20 to fuel dispenser. Branch Hose is used to connect between fuel dispenser to flame head, uPumper® P4 to flame head.
       Main Hose 1¼ DN32                                 Branch Hose 3/8 DN10

    Fuel Dispenser:

    Fuel distribution between pump station and flame heads.
    T-shape dispenser T 1¼-1¼-1¼            T-shape dispenser T 1¼-3/8-1¼
        Fuel dispenser 1 TO 6                            Fuel dispenser 1 TO 12
    Category: FLAMER
  • SHOWVEN® FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. In order to meet the requirements of different application scenarios we designed two pump station (uPumper® P20 and uPumper® P4) and two flame heads (uFlamer® PF10 and uFlamer® X1800).
     

    Specifications:

    Dimension: 1100×700×1095 mm
    Weight: 285kg
    Housing material: 304 stainless steel
    VOLTAGE: 380V
    Work power: 6000W
    Tank capacity: 250L
    Pump output: 110L/min
    Max. supported Flame heads: 20 heads
    Work TEMP.: -20 – 50℃
    Support Fuel: ISOPAR L
    Compatible Flame Head: PF10, X1800
    Category: FLAMER®
  • SHOWVEN® FLAME SYSTEM SHOWVEN 18m FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head X20, pump station P20H, accumulator model and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed.
     

    Specifications:

    Dimension: 1100×736×1095 mm
    Weight: 285kg
    Housing material: 304 stainless steel
    VOLTAGE: AC 380V
    Work power: 10KW
    Tank capacity: 250L
    Pump output: 110L/min
    Supported X20 heads: 2-3 heads
    Work TEMP.: -20 – 50℃
    Installation suggestions: The horizontal distance between the flame head and P20H is recommended to be within 200m, and the vertical height is recommended to be within 30 meters (can be customized according to the actual situation)
    Category: FLAMER®
  • SHOWVEN FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. uPumper® P4 is a hydraulic-based pump station that supports 4 units of uFlamer® X1800 / PF10.
     

    Specifications:

    Dimension:580 x 420 x 460 mm
    Net Weight:48 kg
    Housing material:304 stainless steel
    Input:AC200-240V / AC100-120V, 50-60Hz
    Work power:1800W
    Tank Capacity:32L
    Max. supported Flame heads:4 heads
    Pump Output:15L/min
    Support Fuel:ISOPAR
    Working Mode:Pressurize / Fueling
    Compatible Flame Head:PF10 / X1800
    Category: FLAMER
  • uFetti Blower is a powerful confetti launcher with output up to 18m, equipped with dual fully automatic confetti dosing hopper and can be controlled both manually or automatically by DMX. Take advantage of the customized high-power blower and optimized Venturi tube design, the confetti can be spread farther and wider.
     

    Specifications:

    Dimension: 880 x 660 x 1295mm
    Weight: 112kg
    Input and power: AC200-240V / AC100-120V, 50/60H; 2200W
    Confetti Hopper: 2, separate control of each hopper
    Hopper Capacity: 2kg paper confetti / hopper *2;  4kg metallic confetti / hopper *2
    Consumption Rate: Paper confetti: 0.9kg/min;  Metallic confetti: 1.8kg/min
    Interface: 3-pin and 5-pin XLR
    Control: Manual, DMX, Wireless DMX (via 5-PIN DMX IN)
    Output: Up to 18m
    Output Angels: 40°-90° (6 adjustable angles)
    Blower Speed Adjustable: Yes (High/Low)
    Output Density Adjustable: Yes
    LED Warning Light: Yes
    Caster: 4 casters with brake
     
     
  • uFlamer Gasboom is the safest gas flamer ever on the market, with a series of safety features including 0.1s super sensitive flame monitoring, cascadable power cut-off E-stop connector, dual high voltage electron igniter, patented “SFT” technology, safety lock, dual magnetic valves, shut-off valve, ARM warning light etc. With 5 types of nozzles optional, 2/4 built-in gas cartridges positions, flame effect height from 2 to 8m ensure versatile applications for both indoor and outdoor events.
     

    Specifications:

    Dimension: 320 x 310 x 325 mm
    Weight: 13kg
    Input and power: 100-240VAC, 50/60 Hz; 200W
    Housing Material: 304 stainless steel
    Effect Direction: Vertical
    Flame Height: 2-8m (nozzle size, firing time etc.)
    E-Stop Interface: Yes, can be connected in series
    Dual Magnetic Valves: Yes, connect in series
    High Sensitive Flame Monitoring: Yes, sensitivity up to 0.1s
    Interface: NEUTRIK POWERCON TRUE1 IN/OUT; Waterproof 3-pin and 5-pin XLR IN/OUT
    Control: DMX 512, 9-60V voltage input; Wireless, with Wirelss DMX Receiver (5-PIN DMX IN with DC5V power supply)
    Ignition: High Voltage Electron Ignition×2
    Built-in Battery Design: Yes, 4×18650 Lithium cells
    Waterproof Level: Can be used in heavy rain
    Firing Duration: 0.1-10s
    Fuel: LPG propane or butane gas, gas cartridges bottle, aerosol cartridges
    Cartridge Holder: Twin cartridge holder with 2 shut-off valves and 2 non-return valves; Quadruple cartridge holder with 4 shut-off valves and 4 non-return valves (optional)
    Micro Filter: Yes, installed between shut-off and non-return valves
    Category: FLAMER