    CIRCLE FLAMER X-F1800 is a fluid driven flamer system with 210°swiveling angles.It is a fluid driven flame system with a high accuracy swiveling head, allows for fast and precise flame bursts. The flames height up to 8-10m and equipped with 88 preset flame sequences of flame effects, all of which can be easily achieved with SHOWVEN® original host controller, DMX console or fireworks firing system.

    Specifications:

    MODEL: X-F1800 DIMENSION: 590×360×370mm WEIGHT: 30kg VOLTAGE: 220V/110V, 50/60Hz POWER: 380W CONTROL: DMX, Pyro INTERFACE: Neutrik®powerCON TRUE1 IN/OUT Neutrik® 3-pin& 5-pin XLR IN/OUT 9V-60V Fireworks igniter signal port FLAME HEIGHT: up to 8-10m (no wind) ROTATE ANGLES: 210°(±105°) FUEL: ISOPAR-G, H, L, M; ISOPROPANOL FUEL TANK CAPACITY: 10L FUEL CONSUMPTION RATE: 60ml/s EXT. BATTERY POWERED: YES
    Category: CIRCLE FLAMER
  • ——Redefine Flamer
    CIRCLE FLAMER X-F3600, is a never seen flamer effects originally introduced by SHOWVEN®. It is the first machine in the world with circle flame effects. DMX signal control, full cycle and half cycle mode switchable, 1080°(3 cycles)  rotation nozzle with up to 182 preset firing sequences ensure the versatile use in various professional shows. It is easier and stable to program CIRCLE FLAMER when combined with SHOWVEN® original host controller ZK6200/6300.

    Specifications:

    MODEL: X-F3600 ROTATION MODE:FULL CIRCLE MODE/HALF CIRCLE MODE DIMENSION: 640×360×370mm WEIGHT: 30kg VOLTAGE: 220V/110V, 50/60Hz POWER: 380W CONTROL: DMX, Pyro INTERFACE: Neutrik®powerCON TRUE1 IN/OUT Neutrik® 3-pin& 5-pin XLR IN/OUT 9V-60V Fireworks igniter signal port FLAME HEIGHT: up to 8-10m (no wind) ROTATE ANGLES: 1080° (up to 3 cycles) FUEL: ISOPAR-G, H, L, M; ISOPROPANOL FUEL TANK CAPACITY: 10L FUEL CONSUMPTION RATE: 60ml/s EXT. BATTERY POWERED: YES
    Category: CIRCLE FLAMER
  • uFlamer® is a global pioneer of vertical fluid driven flamer, with flame height up to 8-10m. Equipped with built-in fuel tank and pumping system makes it super easy to setup and operate. The fuel for uFlamer is ISOPAR, which is much safer as well as less restrictions comparing with existing gas flamers on the market.IPX3 rated design and indoor nozzle optional ensure flexible usage of uFlamer®.

    Specifications:

    Model: uFlamer
    Dimension: 330 x 260 x 320 mm Weight: 14kg VOLTAGE: 100-240V, 50/60Hz POWER: 300W CONTROL: DMX INTERFACE: 3-pin&5-pin DMX IN/OUT FLAME HEIGHT: 8-10m (no wind) FUEL: ISOPROPANOL, ISOPAR-G,H,L,M FUEL TANK CAPACITY: 5L FUEL CONSUMPTION RATE: 60ml/s FUEL LEVEL SENSOR: YES EFFECT DIRECTION: Vertical LGNITION: High voltage electron ignition IGNITOR: Dual BUILT-IN BATTERY: OPTIONAL USAGE IN RAIN: YES
    Category: CIRCLE FLAMER
  • uFlamer® Volcano is high end liquid flamer system with five nozzles, each nozzle can firing individually or simultaneously. Volcano with 90 preset firing sequences, 25L built-in fuel tank and pumping system, multi safety design and reliable valve component allowing operators to create spectacular firing effects much easier. It is an ideal choice for fireworks displays, outdoor concert, opening ceremony, sports, scenic area etc.

    Specifications:

    DIMENSION: 630×450×400mm WEIGHT: 48kg HOUSING MATERIAL: 304 stainless steel VOLTAGE: 220v/110V, 50/60Hz WORK POWER: 2000W FLAMER HEIGHT: 8-10m FLAME ANGLES: 5 directions FUEL: ISOPAR, ISOPROPANOL FUEL TANK CAPACITY: 25L FUEL CONSUMPTION: 60mL/s per nozzle WORK TEMP.: -20℃ to 50℃ INTERFACE: SEETRONIC 3-PIN & 5-PIN XLR, Neutrik® PowerCON TRUE1 IGNITION: High voltage electron ignition CONTROL: DMX, 9-60V Pyro USAGE IN RAIN: YES
    Category: FLAMER
  • SHOWVEN® FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. In order to meet the requirements of different application scenarios we designed two pump station (uPumper® P20 and uPumper® P4) and two flame heads (uFlamer® PF10 and uFlamer® X1800).

    Specifications:

    Dimension: 1100×700×1095 mm Weight: 285kg Housing material: 304 stainless steel VOLTAGE: 380V Work power: 6000W Tank capacity: 250L Pump output: 110L/min Max. supported Flame heads: 20 heads Work TEMP.: -20 – 50℃ Support Fuel: ISOPAR L Compatible Flame Head: PF10, X1800
    Category: FLAMER®
  • SHOWVEN FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. In order to meet the requirements of different application scenarios we designed two pump station (uPumper® P20 and uPumper® P4) and two flame heads (uFlamer® PF10 and uFlamer® X1800).

    Specifications:

    Dimension:580 x 420 x 460 mm Net Weight:48 kg Housing material:304 stainless steel Input:AC200-240V / AC100-120V, 50-60Hz Work power:1800W Tank Capacity:32L Max. supported Flame heads:4 heads Pump Output:15L/min Support Fuel:ISOPAR Working Mode:Pressurize / Fueling Compatible Flame Head:PF10 / X1800 (Pressurize), uFlamer® Volcano (Fueling)
    Category: FLAMER
  • SHOWVEN FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. In order to meet the requirements of different application scenarios we designed two pump station (uPumper® P20 and uPumper® P4) and two flame heads (uFlamer®PF10 and uFlamer® X1800).

    Specifications:

    Dimension:250 x 200 x 410 mm Net Weight:15 kg Housing material:Aluminum Input:220V, 110V, 24V customizable Work power:120W Flame height:Up to 10m Fuel: ISOPAR Fuel consumption: 60ml/s (Nozzle M), 30ml/s (Nozzle L) Ignition: Dual, high voltage electron ignition Control: DMX, Direct ON-OFF customizable Quick Couplers: ISO7241B G1/4 male Work pressure range: 8-12bar Installation angles: Any direction even upside down
    Category: FLAMER
  • SHOWVEN® FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. In order to meet the requirements of different application scenarios we designed two pump station (uPumper® P20 and uPumper® P4) and two flame heads (uFlamer® PF10 and uFlamer® X1800).

    Specifications:

    Dimension:370 x 380 x 380 mm Net Weight:19 kg Housing material:304 Stainless steel Input:220V, 110V Work power:260W Flame height:Up to 10m USAGE IN RAIN: yes Quick Couplers: ISO7241B G1/4 male Min. firing duration: 0.1s Firing Angle: 210° (±105°) Fuel: ISOPAR Fuel consumption: 60ml/s (Nozzle M), 30ml/s (Nozzle L) Ignition: Dual, high voltage electron ignition Control: DMX, 9-60V Pyro signal USAGE IN RAIN: yes WORK PRESSURE RANGE: 8-12bar INSTALLATION ANGLES: Any direction, bottom plate need protective cover (optional) to achieve waterproof function
    Category: FLAMER
  • SHOWVEN FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head, pump station, control box and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed. Any installation direction of flame heads brings endless design inspiration to event planners. In order to meet the requirements of different application scenarios we designed two pump station (uPumper® P20 and uPumper® P4) and two flame heads (uFlamer® PF10 and uFlamer® X1800).

    Hose:

    High pressure steel wire braided rubber hose. Main hose is used to connect between uPumper® P20 to fuel dispenser. Branch Hose is used to connect between fuel dispenser to flame head, uPumper® P4 to flame head.
       Main Hose 1¼ DN32                                 Branch Hose 3/8 DN10

    Fuel Dispenser:

    Fuel distribution between pump station and flame heads.
    T-shape dispenser T 1¼-1¼-1¼            T-shape dispenser T 1¼-3/8-1¼
        Fuel dispenser 1 TO 6                            Fuel dispenser 1 TO 12
    Category: FLAMER
  • uFlamer Gasboom is the safest gas flamer ever on the market, with a series of safety features including 0.1s super sensitive flame monitoring, cascadable power cut-off E-stop connector, dual high voltage electron igniter, patented “SFT” technology, safety lock, dual magnetic valves, shut-off valve, ARM warning light etc. With 5 types of nozzles optional, 2/4 built-in gas cartridges positions, flame effect height from 2 to 8m ensure versatile applications for both indoor and outdoor events.

    Specifications:

    Dimension: 320 x 310 x 325 mm Weight: 13kg Input and power: 100-240VAC, 50/60 Hz; 200W Housing Material: 304 stainless steel Effect Direction: Vertical Flame Height: 2-8m (nozzle size, firing time etc.) E-Stop Interface: Yes, can be connected in series Dual Magnetic Valves: Yes, connect in series High Sensitive Flame Monitoring: Yes, sensitivity up to 0.1s Interface: NEUTRIK POWERCON TRUE1 IN/OUT; Waterproof 3-pin and 5-pin XLR IN/OUT Control: DMX 512, 9-60V voltage input; Wireless, with Wirelss DMX Receiver (5-PIN DMX IN with DC5V power supply) Ignition: High Voltage Electron Ignition×2 Built-in Battery Design: Yes, 4×18650 Lithium cells Waterproof Level: Can be used in heavy rain
    Firing Duration: 0.1-10s
    Fuel: LPG propane or butane gas, gas cartridges bottle, aerosol cartridges Cartridge Holder: Twin cartridge holder with 2 shut-off valves and 2 non-return valves; Quadruple cartridge holder with 4 shut-off valves and 4 non-return valves (optional) Micro Filter: Yes, installed between shut-off and non-return valves
    Category: FLAMER
  • SHOWVEN® FLAME SYSTEM SHOWVEN 18m FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head X20, pump station P20H, accumulator model and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed.

    Specifications:

    Dimension: 1100×736×1095 mm Weight: 285kg Housing material: 304 stainless steel VOLTAGE: AC 380V Work power: 10KW Tank capacity: 250L Pump output: 110L/min Supported X20 heads: 2-3 heads Work TEMP.: -20 – 50℃ Installation suggestions: The horizontal distance between the flame head and P20H is recommended to be within 200m, and the vertical height is recommended to be within 30 meters (can be customized according to the actual situation)
    Category: FLAMER®
  • SHOWVEN 18m FLAME SYSTEM is a hydraulic based flame effect solution for project or truss mounted installations. It is consist of flame head X20, pump station P20H, accumulator model and accessories such as hoses, cables etc. It can easily achieve remote fuel supply with the pump station and no nitrogen tank needed.

    Specifications:

    Dimension:330 x 330 x 320 mm Weight:18 kg Housing material:304 stainless steel Input:AC100-240V, 50/60Hz Work power:100W Flame height:16-18m(no wind) Usage in Rain: Yes Fuel consumption:1000ml/s Ignition: Triple, high voltage electron ignition Control: DMX, 9-60V pyro signal Quick Couplers: ISO7241B G1/4 male Work pressure range: 40-60Bar
    Firing Angle: Vertical Up Installation Direction: Vertical Up
    Fuel: ISOPAR L (if use with uPumper P20H)
    Pressure Gauge: Yes, mechanical
    Min.Firing Duration: 0.2s
    Max.Firing Duration: 1s
    Category: FLAMER